        Mechanical and Electrical Interface Size (w x h x l) 56 x 60 x 39.4 mm Lens mount C, F, T2, M42 x 1 – Sensor alignment (See “Sensor Alignment” on page 16) ?x,y = ±50 – ?z = ±30 – ?tiltz = 0-35 ?θx,y = ±0.2 μm ° Power supply DC, single 12 to 24V V Power dissipation < 7 W Operating temperature(3) 0 to 65 (non condensing) °C Storage temperature -40 to 75 (non condensing) °C

        Camera Synoptic The Camera Link line scan is based on a two-tap linear CCD. Therefore, two analog chains process odd and even pixel outputs of the linear sensor. The CCD signal processing encompasses the correlated double sampling (CDS), the dark level correction (dark pixel clamping), the gain (PGA) and offset correction and finally the analog to digital conversion on 12-bit. Note: PGA stands for Programmable Gain Array. The camera is powered by a single DC power supply from 12V to 24V. The functional interface (data and control) is provided with the Camera Link interface. The camera uses the base configuration of Camera Link standard. Note: DVAL = 1 and FVAL = 0 The data can be delivered either on two channels or on a single multiplexed channel. The data format can be configured in 8-, 10- or 12-bit. The camera can be used with external triggers (TRIG1 and TRIG2 signals) in different trigger modes (see “Synchronization Mode” on page 6). The camera can be also clocked externally, allowing system synchronization and/or multi-camera synchronization. The camera configuration and settings are performed via a serial line. This interface is used for:

         ? Gain, offset setting

         ? Dynamic range, data rate setting

         ? Trigger mode setting: free run or external trigger modes

         ? Integration time setting: in free running and external trigger mode Linear CCD 2 taps CCD Drivers Even pixels analog chain PGA, CDS, ADC 12-bit at 30 Mpixels/s Odd pixels analog chain PGA, CDS, ADC 12-bit at 30 Mpixels/s Microcontroller CameraLinkTM transceiver TX RX Power supplies DC power Camera LinkR I/F Sequencer controller DATA Serial line TRIG1,

         Standard Conformity The cameras have been tested in the following conditions: 

         ? Shielded power supply cable 

         ? Camera Link® data transfer cable ref. 14B26-SZLB-500-OLC (3M 

         ? Linear AC-DC power supply 

         ? e2v recommends using the same configuration to ensure the compliance with the following standards