Typical Performances Note:
1. LSB are given for 12-bit configuration
2. nJ/cm2 measured on the sensor Table 4-1. Typical Performances Parameter Value Unit Sensor Characteristics at Maximum Pixel Rate Resolution 512 1024 2048 4096 pixels Pixel size (square) 14 – 14 10 14 10 – 10 μm μm Max Line rate 98 53 28 14 kHz Anti blooming x 150 – Radiometric Performances (Maximum Pixel Rate, Tamb = 25°C) Output format 12 (also configurable in 8 or 10) bit Spectral range 250 - 1100 nm Linearity < 1 % Gain range (step of 0.047 dB) Gmin 0 Gnom 18 Gmax 30 dB Peak response(1)(2) with 14 μm pitch 10 μm pitch 130 50 1040 400 4180 1600 LSB/(nJ/cm2 ) LSB/(nJ/cm2 ) Dynamic Range Effective bit 67.4 11.2 49 8.2 37 6.2 dB bit Input RMS Noise with 14 μm pitch 10 μm pitch 14 37 pJ/cm2 pJ/cm2 PRNU (Pixel Response Non Uniformity) ± 3% (± 10% max) % Mechanical and Electrical Interface Size (w x h x l) 56 x 60 x 39.4 mm Lens mount C, F, T2, M42 x 1 – Sensor alignment (See “Sensor Alignment” on page 16) ?x,y = ±50 – ?z = ±30 – ?tiltz = 0-35 ?θx,y = ±0.2 μm ° Power supply DC, single 12 to 24V V Power dissipation < 7 W Operating temperature(3) 0 to 65 (non condensing) °C Storage temperature -40 to 75 (non condensing) °C pixel 10x10 μm pixel 14x14 μm 0% 20% 40% 60% 80% 100% 200 400 600 800 1000
5-1. Camera Synoptic The Camera Link line scan is based on a two-tap linear CCD. Therefore, two analog chains process odd and even pixel outputs of the linear sensor. The CCD signal processing encompasses the correlated double sampling (CDS), the dark level correction (dark pixel clamping), the gain (PGA) and offset correction and finally the analog to digital conversion on 12-bit. Note: PGA stands for Programmable Gain Array
Even pixels analog chain PGA, CDS, ADC 12-bit at 30 Mpixels/s Odd pixels analog chain PGA, CDS, ADC 12-bit at 30 Mpixels/s Microcontroller CameraLinkTM transceiver TX RX Power supplies D
The camera is powered by a single DC power supply from 12V to 24V. The functional interface (data and control) is provided with the Camera Link interface. The camera uses the base configuration of Camera Link standard. Note: DVAL = 1 and FVAL = 0 The data can be delivered either on two channels or on a single multiplexed channel. The data format can be configured in 8-, 10- or 12-bit. The camera can be used with external triggers (TRIG1 and TRIG2 signals) in different trigger modes (see “Synchronization Mode” on page 6). The camera can be also clocked externally, allowing system synchronization and/or multi-camera synchronization. The camera configuration and settings are performed via a serial line. This interface is used for: