TYPICAL PROPERTIES (1)
|
MECHANICAL/机械性能
|
value/值
|
Unit/单位
|
Standard/标准
|
Tensile Stress, brk, Type I / 抗张程度,断裂,类型I, 5 mm/min
|
106
|
MPa
|
ASTM D 638
|
Tensile Strain, brk, Type I / 拉伸伸长,断裂,类型I, 5 mm/min
|
5
|
%
|
ASTM D 638
|
Flexural Stress, yld / 挠曲强度, 屈服 , 2.6 mm/min, 100 mm span
|
151
|
MPa
|
ASTM D 790
|
Flexural Modulus / 挠曲模量, 2.6 mm/min, 100 mm span
|
5720
|
MPa
|
ASTM D 790
|
Hardness,Rockwell / 洛氏硬度 L
|
106
|
-
|
ASTM D 785
|
IMPACT/冲击性能
|
value/值
|
Unit/单位
|
Standard/标准
|
Izod Impact, notched / 悬臂梁缺口冲击强度, 23°C
|
106
|
J/m
|
ASTM D 256
|
Izod Impact, notched / 悬臂梁缺口冲击强度, -40°C
|
96
|
J/m
|
ASTM D 256
|
THERMAL/热性能
|
value/值
|
Unit/单位
|
Standard/标准
|
HDT(热变形温度), 0.45 MPa, 6.4 mm, unannealed (未退火)
|
137
|
°C
|
ASTM D 648
|
HDT(热变形温度), 1.82 MPa, 6.4 mm, unannealed (未退火)
|
132
|
°C
|
ASTM D 648
|
CTE(线形膨胀系数), -40°C to 95°C, flow(流动)
|
3.6E-05
|
1/°C
|
ASTM E 831
|
Relative Temp Index, Elec / 相对热指数, 电性能
|
110
|
°C
|
UL 746B
|
Relative Temp Index, Mech w/impact / 相对热指数,机械冲击性能
|
105
|
°C
|
UL 746B
|
Relative Temp Index, Mech w/o impact / 相对热指数,非机械冲击性能
|
110
|
°C
|
UL 746B
|
PHYSICAL/物理性能
|
value/值
|
Unit/单位
|
Standard/标准
|
Specific Gravity / 比重
|
1.23
|
-
|
ASTM D 792
|
Water Absorption / 吸水率, 24 hours
|
0.06
|
%
|
ASTM D 570
|
Mold Shrinkage / 收缩率, flow(流动), 3.2 mm
|
0.2 - 0.5
|
%
|
SABIC Method
|
ELECTRICAL/电气性能
|
value/值
|
Unit/单位
|
Standard/标准
|
Dielectric Strength, in oil / 耐电强度,在油中, 3.2 mm
|
23.6
|
kV/mm
|
ASTM D 149
|
Relative Permittivity / 相对介电常数, 50/60 Hz
|
2.98
|
-
|
ASTM D 150
|
Dissipation Factor / 耗散因素, 50/60 Hz
|
0.0016
|
-
|
ASTM D 150
|
Arc Resistance, Tungsten / 耐电弧性 {PLC}
|
7
|
PLC Code
|
ASTM D 495
|
Hot Wire Ignition / 热丝引燃 {PLC)
|
0
|
PLC Code
|
UL 746A
|
High Voltage Arc Track Rate / 高电压电弧起痕速率 {PLC}
|
4
|
PLC Code
|
UL 746A
|
High Ampere Arc Ign, surface / 高电流电弧引燃,表面 {PLC}
|
1
|
PLC Code
|
UL 746A
|
Comparative Tracking Index / 相比耐漏电起痕指数 (UL) {PLC}
|
1
|
PLC Code
|
UL 746A
|
FLAME CHARACTERISTICS/火焰特性
|
value/值
|
Unit/单位
|
Standard/标准
|
UL Recognized, 94V-1 Flame Class Rating / 阻燃等级 (3)
|
1.47
|
mm
|
UL 94
|
UL Recognized, 94V-0 Flame Class Rating / 阻燃等级 (3)
|
5.99
|
mm
|
UL 94
|
UL Recognized, 94-5VA Rating (3)
|
2.5
|
mm
|
UL 94
|
Oxygen Index / 极限氧指数 (LOI)
|
30.9
|
%
|
ASTM D 2863
|